What was found
FWD SVC DOOR FWD UPPER JAMB CORNER CRACKED 1/4 INCH. C/A INSTALLED DOUBLER REPAIR IAW DWG SR08530021, SRM 53-4-1 FIG 9 ITEM D, AND AD-2000-20-08 S/BDC8-53-075.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD SVC DOOR FWD UPPER JAMB CORNER CRACKED 1/4 INCH. C/A INSTALLED DOUBLER REPAIR IAW DWG SR08530021, SRM 53-4-1 FIG 9 ITEM D, AND AD-2000-20-08 S/BDC8-53-075.