As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING FLIGHT CREW NOTICED AN ELECTRICAL ODOR. DIVERTED FLIGHT & DECLARED AN EMERGENCY. FOUND THE NR 1 EMERGENCY LIGHT POWER SUPPLY BAD. OPS CHECKED PASSED. BOTH EMER POWER SUPPLIES WERE REPLACED IAW SERVICE BULLETIN 33-0007. ALSO REPLACED THREE EMERGENCY LIGHTS. OPS CHECKED GOOD & THE ACFT RETURNED TO SERVICE.