Service difficulty report · Thermal Switch · Emb EMB505

Difficulty date
August 13, 2016
Submitted
August 18, 2016
Operation
Air carrier
Aircraft
N347FX
Make and model
Emb EMB505
Aircraft serial
50500094
Aircraft time
1,933 hours, 1,397 cycles
Part
Thermal Switch
Condition
Defective
Location
Bleed Air Sys
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DIVERTED DUE TO "BLEED 2 LEAK" CAS MESSAGE. COMPLETED QRH PROCEDURE AND CAS MESSAGE CLEAR. DURING DECENT CAS MESSAGE CAME BACK. COMPLETED QRH PROCEDURES TO SECOND END POINT AND CAS MESSAGE CLEARED AND REMAINED OFF FOR REMAINDER OF FLIGHT. CREW DECLARED AN EMERGENCY. LANDED WITHOUT INCIDENT. REPLACED TWO BLEED LEAK THERMAL SWITCHES ON INBOARD AND OUTBOARD OF RT PYLON PRECOOLER. OPS CHECK GOOD.