What was found
A/C ABORTED TAKEOFF AT 50 KTS FOR RT HYD PRESS AND RT HYD QUANTITY. FOUND NORMAL ANTI-SKID NR 2 FUSE VALVE LEAKING AND LOOSE EDP PRESS LINE ON NR 2 ENG. REPLACED VALVE WITH UNIT FROM UPS AT MIA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
A/C ABORTED TAKEOFF AT 50 KTS FOR RT HYD PRESS AND RT HYD QUANTITY. FOUND NORMAL ANTI-SKID NR 2 FUSE VALVE LEAKING AND LOOSE EDP PRESS LINE ON NR 2 ENG. REPLACED VALVE WITH UNIT FROM UPS AT MIA.