What was found
INTERMITTANT ELEC ODOR THROUGHOUT ACFT FOLLOWED BY A L RECIR FAN EICAS WITH ASSOC INOP LIGHT IN L RECIRC SWITCH ON OVERHEAD. SWITCH TURNED OFF AND CB PULLED R14. NORMAL OPS AFTERWARDS. REPLACED LT RECIRC FAN.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INTERMITTANT ELEC ODOR THROUGHOUT ACFT FOLLOWED BY A L RECIR FAN EICAS WITH ASSOC INOP LIGHT IN L RECIRC SWITCH ON OVERHEAD. SWITCH TURNED OFF AND CB PULLED R14. NORMAL OPS AFTERWARDS. REPLACED LT RECIRC FAN.