What was found
PYLON, NR 1 FWD UPPER SPAR WEB, POWER FEEDER CABLE CUTOUT CRACKS. TWO CRACKS WERE FOUND IN THE UPPER SPAR WEB FROM THE POWER FEEDER CUTOUT TO THE NUTPLATE ATTACH HOLES. ERA INSTALLED REPAIR DOUBLER AND FILLER PER S/B 767-54-0090._ERA 385462-14 REVISION ORIGINAL. ETOPS CATEGORY 'E': PROBLEMS WITH SYSTEMS CRITICAL TO ETOPS.