What was found
RUDDER RATIO AND AILERON LOCKOUT EICAS MESSAGE AND LIGHT ON OVERHEAD. ALSO L.C. AND R AUTOPILOTS WOULD NOT ENGAGE. T/S FOUND FAULT BALL SHOWS ON BOTH SAM. RESET AND PERFORMED MCDP TEST 1/30/40/65. FAILED FCCR SAM. ALSO FAULT BALL SHOWS ON RT SAM. R & R RT SAM MM. PERFORMED MCDP TEST 1/30/40 AND 65. ALL PASS NO FAULT BALL SHOWS ON SAM. ALL CHECK OK. ETOPS CATEGORY 'E': PROBLEMS WITH SYSTEMS CRITICAL TO ETOPS.