What was found
AFTER TAKEOFF 1.5 HOURS INTO FLIGHT, SMELLED ELECTRICAL FUMES IN COCKPIT ACCOMPANIED BY FWD EQUIPMENT EXHAUST FAN STATUS MESSAGE ON EICAS. CALLED FLIGHT CONTROL AND MTC COORDINATOR TO DISCUSS SITUATION AND DECIDED TO PULL P-22 CB. FUMES DISSIPATED AND FLIGHT WAS CONTINUED. UPON FURTHER INVESTIGATION FOUND THE FWD EXH EQUIP COOL FAN C/B ON P-6 PANEL POPPED. REPLACED FWD EQUIPMENT EXHAUST FAN, SYSTEM CHECKS NORMAL.