What was found
DURING CRUISE, SYSTEM NR 2 HYD QTY WENT TO ZERO. FOUND O-RING PACKING ON LOW PRESS SWITCH RT EDP NR 2 SYSTEM DETERIORATED. REPLACED PACKING/SVCD NR 2 HYD SYS/LEAK AND OPS CK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.