What was found
STRONG ELECTRICAL ODOR REPORTED IN AFT CABIN ON CLIMBOUT AT 15,000 FT. ODOR WAS SMELLED IN COCKPIT SOON AFTERWARD. RETURNED TO ATL. PERFORMED DUCT BURN-OUT. REPLACED COALESCER BAGS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRONG ELECTRICAL ODOR REPORTED IN AFT CABIN ON CLIMBOUT AT 15,000 FT. ODOR WAS SMELLED IN COCKPIT SOON AFTERWARD. RETURNED TO ATL. PERFORMED DUCT BURN-OUT. REPLACED COALESCER BAGS.