As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
S/O 291025 N/R 25189 CORROSION IN SCREW HOLES AND DRILLED OFF SCREWS AT SUPPORT BEAM AFT PIT FLOOR LEVEL S-27R FROM BS 1380 TO 1440. OVERSIZED HOLE, INSTALLED FREEZE PLUG, FABRICATED AND INSTALLED REPAIR STRAP 2.50 INCHES X .90 INCHES FROM 7075-T6 .063 INCH IAW SRM 51-20-07, 51-40-2 AND 51-20-01.