What was found
PERFORM VISUAL INSPECTION OF THE RT LINE ASSY P/N 6516311-19 (REFUEL/DEFUEL FLOW) FOR SIGNS OF CHAFFING BY FLAP CROSS OVER CABLE BEHIND PANEL 172BB. (CHAPT. 6 ACCESS PLATES AND PANELS INDENTIFICATION. CE-560E MM 6-20-02 FIG 2 PG 12 OF 14). GAINED ACCESS FOR INSPECTION AND FOUND THAT SINGLE POINT FUEL LINE CHAFFED BEYOND LIMITS. 8/7 REMOVED FUEL LINE. 8/8 OK TO INSTALL NEW FUEL LINE 8/8 INSTALLED NEW FUEL LINE IAW 560 MM 20-10-13. 8/8 OK TO CLOSE AND SEAL ACCESS PANELS. 8/8 CLOSED ALL PANELS, SEALED OVERWING FILLET PANEL IAW 560 MM 20-32-00. 8/8 SEALANT NEEDS PAINT APPLIED TOUCH UP PAINT AS REQ. 8/8 LEAK CHECKED GOOD 8/8.