What was found
RUDDER LIMIT FAIL A EICAS MESSAGE. CONTROL PAGE SHOWS 43 PERCENT RUD LIMIT. REMOVED UPPER RUDDER -A- LINEAR ACTUATOR DUE TO INTERNAL FAILURE. INSTALLED OVERHAULED UNIT. OPERATIONAL CHECK WAS GOOD. WORK WAS DONE IAW CE-750 MM 27-23-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RUDDER LIMIT FAIL A EICAS MESSAGE. CONTROL PAGE SHOWS 43 PERCENT RUD LIMIT. REMOVED UPPER RUDDER -A- LINEAR ACTUATOR DUE TO INTERNAL FAILURE. INSTALLED OVERHAULED UNIT. OPERATIONAL CHECK WAS GOOD. WORK WAS DONE IAW CE-750 MM 27-23-00.