What was found
FLAPS FAILED IN UP POSITION DEPARTING KBUF, WOULD NOT RESET, DIVERTED TO CMH. VISUALLY INSPECTED FLAPS AND FLAPWELL COMPONENTS. LUBRICATED ACTUATOR BALLSCREWS PER CE-750 M/M 12-20-05. RESET BITE CODES ON FLAP CONTROLLER. CHECKED RESOLVER CONVERTER VOLTAGE OUT PUTS UNDER NORMAL AND FREEZING CONDITIONS. NO DEFECTS NOTED. CYCLED FLAPS SEVERAL TIMES AND VERIFIED NO MORE BITE CODES WERE TRIPPED. PERFORMED ROTARY TEST OF FLAPS. CHECKS GOOD. COULD NOT DUPLICATE ORIGINAL FAULT, C/W IAW CE-750 M/M 27-50-00.