What was found
LOWERED LANDING GEAR AND GOT THREE GREEN LIGHTS AND 2 RED LIGHTS. RETRACTED LANDING GEAR AND GOT NO GREEN LIGHTS AND 2 RED LIGHTS CYCLED GEAR SEVERAL TIMES AND GOT SOME INDICATIONS, DID EMERGENCY GEAR EXTENSION GOT NORMAL GEAR INDICATION 3 GREEN. VERIFIED ADJUSTMENT OF MLG DOOR UPLOCK SWITCHES REF 32-10-00-212, PERFORMED VISUAL INSPECTION OF LANDING GEAR UPLOCK, DOWNLOCK AND WIRING INSTALLATION AND LUBED DOOR UPLOCK MECHANISM, CYCLED LANDING, GEAR MULTIPLE TIMES (30+), UNABLE TO DUPLICATED SQUAWK, NO DEFECTS NOTED AT THIS TIME.