As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DOOR LEAKS AIR AND WHISTLES AT FL410. FOUND SUPPLY TUBE TO LOWER ACOUSTIC DOOR SEAL PINCHED PREVENTING SEAL FROM INFLATING. REPOSITIONED TUBE IAW CE 750 M.M. 52-10-04 OPS CHECK GOOD. ALSO ADJUSTED PRE-CATCH IAW CE 750 M.M. 52-10-01. DOOR NO LONGER HARD TO CLOSE. NOTE: DOOR CABLES ADJUSTED TO MAX SPEC- 220 LBS.