What was found
DURING ENGINE START, LT ENGINE OIL PRESSURE WOULD NOT COME OUT OF THE RED . AFTER APPROX 15 SEC ITT CLIMBED TO 680 DEG C AND THEN SHOT UP TO 800 DEG C FOR 2-3 SECS . AS SOON AS ITT WENT PAST 720 DEG START WAS ABORTED . ITT WAS NOT AT 800 DEG C FOR MORE THAN 3 SECS. MOTORED ENGINE FOR 30 SEC AFTER ABORT. ITT DROPPED BELOW 720 DEG C AS SOON AS START WAS ABORTED AND CONTINUED TO DROP WILE LT ENGINE WAS MOTORED . INSPECTED LT ENGINE AND OIL LEVEL WAS NORMAL. COMPLIED WITH DCU DOWNLOAD OF LT ENGINE, SENT DOWNLOAD INFO TO PWC FOR INTERPROLATION, PWC REPORT NO EXCEEDANCES AT THIS TIME. P&WC RECOMMENDS STARTING & GROUND RUNNING ENGINE TO CHECK OPERATION. COMPLIED WITH THESE RECOMMENDATIONS ENGINE OPS CKS GOOD PER