What was found
RT MAIN LANDING GEAR WOULD NOT RETRACT. HAD RED UNSAFE EICAS INDICATION. CONFIRMED DISCREPANCY. TROUBLESHOT AND DISCOVERED CONNECTOR 44G1J TO HAVE AMPLE AMOUNT OF WATER IN IT. CLEANED AND DRIED CONNECTOR AND RECONNECTED. SWUNG GEAR THROUGH SEVERAL CYCLES WITH NO DEFECTS NOTED. APPLIED SEALANT TO BACK OF CONNECTOR TO PREVENT WATER INTRUSION. C/W CMP 323001 NORMAL FUNCTIONAL TEST. WORK DONE IAW G200 REF 32-10-10 & 32-10-15.