What was found
HYD A PRESSURE DROPPED TO 2000 PSI, FOLLOWED BY AMBER CAS (HYD LOW QTY B) AND (HYD O TEMP B) MESSAGES ILLUMINATED. REMOVED & REPLACED PTU, LH ENGINE DRIVEN HYD. PUMP & "A" HYD FILTER ASSEMBLY, IAW THE 750 MAINT. MANUAL 29-10-02, 29-10-09 & 29-20-04. OPERATIONAL/LEAK CHECK SATISFACTORY. REPLACED ALL 'A' HYD SYSTEM FILTER. LEAK CHECK SATISFACTORY.