As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PCU MONITOR CB POPPED AND FLIGHT CONTROL FAULT EICAS MESSAGE APPEARED DESENDING THROUGH 6000 FT RUDDER FLT CONTROL SHUT OFF SW ALSO ILLUMINATED. [07-12-07] T/S TO BAD ELEVATOR OUTOBARD PCU ("B" SYS) REMOVED AND REPLACED PCU. PERFORMED RIG CHECKS. SYSTEM LEAKS & OP'S CHECKS SATISFACTORY AT THIS TIME. ALL WORK DONE IAW CE750 M/M 27-30-00