As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLAPS FAIL EICAS IN FLIGHT FOLLOWED FLAP RESET PROCEDURE IAW CHECK LIST NO RESPONSE. DID NO FLAP LANDING. REMOVED FAULTY LEFT FLAP POWER CONVERTER AND #2 FLAP POSITION SENSOR. INSTALLED INSPECTED FLAP SENSOR BY MPC PRODUCTS CRS M 74R907N AND INSTALLED NEW LEFT CONVERTER AND PERFORMED FLAP OPS CHECK GOOD. IAW C750 M.M. 27-50-00.