What was found
FLAPS WOULD NOT EXTENDED IN FLIGHT, PRESSING FLAPS RESET BUTTON & PULLING FLAP CONTROL CB DID NOT FIX THE PROBLEM. PERFORMED AN OPERATIONAL CHECK OF THE FLAP SLAT SYSTEMS SEVERAL TIMES FROM THE FULL DEPLOY TO THE FULL STOW POSITIONS. FOUND THE FLAPS & SLATS FOLLOWED THE INDICATIONS IN THE COCKPIT AS REQUIRED. PULLED SLAT A & SLAT B CB'S INDEPENDANTLY & MOVED HANDLE & SLAT FAIL CAS MESSAGE ANNUNCIATOR AS REQUIRED. RESET CB'S & SYSTEM FUNCTIONED AS REQUIRED W/NO DEFECTS NOTED. ALL WORK PERFORMED IAW CE750 MM 27-50-00.