Service difficulty report · Probe · Amd FALCON2000

Difficulty date
December 28, 2007
Submitted
January 7, 2008
Operation
Air carrier
Aircraft
N259QS
Make and model
Amd FALCON2000
Aircraft serial
159
Aircraft time
6,149 hours, 3,813 cycles
Engine
Cfe CFE73811B
Part
Probe
Part number
861CAU2
Part serial
0981A
Condition
Inoperative
Location
Aoa
Part time
6,149 hours, 3,813 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT AUTO SLAT LIGHT AT ROTATION ALONG WITH STALL EYEBROW. NO OTHER ABNORMAL INDICATIONS. STALL EYEBROW INDICATION UNTIL 200 KTS. AUTO SLAT LIGHT WENT OUT 15 MIN INTO FLIGHT. REMOVED LT AOA PROBE AND INSTALLED A MODIFIED AOA PROBE IAW FALCON 2000 AMM 27-813. PERFORMED OPERATIONAL TEST OF THE AOA PROBE IAW FALCON 2000 AMM 27-813 AND AOA PROBE ANTI-ICE TOS IAW FALCON 2000 AMM 30-300 AND OPS TESTS CHECKED GOOD. PERFORMED OPS TEST OF THE SLATS SYSTEM AND OPS TEST CHECKED GOOD IAW FALCON 2000 AMM 27-803. NO DEFECTS NOTED AT THIS TIME.