What was found
ON SHORT FINAL, THE RED UNLOCK LIGHT ILLUMINATED AND THE GEAR WARNING HORN BEGAN TO SOUND. R&R NLG ACTUATOR DOWNLOCK SWITCH OPS CHECK GOOD. SERVICED EMERGENCY GEAR BLOW DOWN ACCUMULATOR . CHECKED HYD LEVELS NO SERVICING REQUIRED. WORK DONE IAW MM 12-10-15, 32-00-01, 33-30-03, 32-60-00, 12-10-35, IPC 3260-00 R&R MLG LOGIC MODULE IAW MM 24-53-00, OPS GOOD.