What was found
ON APPROACH, SELECTED FLAPS TO 35 AND THE FLAPS WENT TO ABOUT 20 AND GOT A FLAPS FAIL EICAS MESSAGE. DOWNLOADED FAULTS BITE CODES 2 AND 8, RESET BITE. OPERATED FLAP SYS SATISFACTORY. ALL FLAP TRAVEL IS GOOD. REPLACED FLAP RELAY KZ089 WITH NEW, IAW MM 27-51-00. OPS CHECK GOOD.