What was found
AT V/R ACFT WOULD NOT ROTATE WITH CONTROL INPUTS AND ELEVATOR /AIL TRIM LIGHT COME ON. DUE TO LOCAL ATMOSPHERIC CONDITIONS. (RAIN/ COLD WEATHER) SUSPECT MOISTURE FOUND IN LWR REAL EQUIPMENT BAY AREA MAY HAVE ACCUMULATED AND FROZE ON PRIMARY AND SECONDARY FLIGHT CONTROL CABLES/ PULLEYS. REMOVED MOISTURE FROM REAR EQUIPMENT BAY AND CLEANED AFFECTED FLIGHT CONTROL CABLES/ PULLEYS. LUBRICATED PRIMARY FLIGHT CONTROLS. (AILERON, RUDDER, ELEVATOR) AND TRIM TABS/ JACKS IAW MFG AFMS PN: AFMS, CHP 007-001-001. PERFORMED FUNCTIONAL TEST OF AILERON CNTRL AND AILERON TRIM CONTROL AND AILERON OUT OF TRIM INDICATOR SYS IAW MM 27-10-00. ALL FOUND WITHIN LIMITS. PERFORMED FUNCTIONAL TEST OF RUDDER AND ELEVATOR CONTROL SECOND TRIM CONTROL SYS IAW MM 27-20-00 AND 27-30-00, ALL FOUND WITHIN LIMITS. PERFORMED ELEVATOR OUT OF TRIM ANNUNCIATOR FUNCTIONAL TEST IAW MM 27-30-00, FUNCTIONAL CHECK GOOD.