Service difficulty report · Actuator · Gulstm 200

Difficulty date
December 23, 2008
Submitted
June 24, 2009
Operation
Air carrier
Aircraft
N740QS
Make and model
Gulstm 200
Aircraft serial
194
Aircraft time
307 hours, 191 cycles
Part
Actuator
Part number
2630000004
Part serial
IL219
Condition
Stiff
Location
Lt Mlg
Part time
191 cycles
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LT MLG WOULD NOT EXTEND, GOT A RED UNSAFE INDICATION. CYCLED GEAR AND WAS ABLE TO EXTEND GEAR NORMALLY. HYD PRESSURE WAS NORMAL AND AUX HYD PUMP DID NOT COME ON. FOUND DOWNLOCK SWITCH ON MAIN LT GEAR HYD ACTUATOR WITH HIGH RESISTANCE. REMOVED LT MAIN GEAR HYD ACTUATOR PN 26300-000-04 SN 1L219. INSTALLED REPAIRED MAIN GEAR HYD ACTUATOR PN 26300-000-04 SN 1L219. INSTALLED REPAIRED MAIN GEAR HYD ACTUATOR PN 26300-000-04 SN IL-172. REF MM 32-10-20. CYCLED LANDING GEAR SEVERAL TIMES AND INSPECTED FOR PROPER OPERATION, NO LEAKS AND NO INTERFERENCE. REF MM 32-10-15. PERFORMED MLG ACTUATOR BLEEDING IAW 32-10-20.