What was found
REPLACED GROUND SEAL PN S3521-6 AT GT048 REMOVED AND REPLACED RT RESOLVE CONVERTER (DUE TO FAIL MSG) ELECTRICAL RIG CHECK GOOD, FLAPS SYS CHECK GOOD IAW MM CH 27-50-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
REPLACED GROUND SEAL PN S3521-6 AT GT048 REMOVED AND REPLACED RT RESOLVE CONVERTER (DUE TO FAIL MSG) ELECTRICAL RIG CHECK GOOD, FLAPS SYS CHECK GOOD IAW MM CH 27-50-00.