Service difficulty report · Shutoff Valve · Gulstm 200

Difficulty date
April 20, 2009
Submitted
September 18, 2009
Operation
Air carrier
Aircraft
N748QS
Make and model
Gulstm 200
Aircraft serial
157
Aircraft time
1,784 hours, 1,085 cycles
Part
Shutoff Valve
Part number
3279555
Part serial
208
Condition
Inoperative
Location
Cabin Air
Part time
1,085 cycles
Stage of operation
CL
How discovered
O
Nature of condition
B, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RED "COCKPIT DUCT TEMP HI" ANNUCIATED AT LIFTOFF. VERY HOT IN COCKPIT & CABIN. SMOKE IN COCKPIT & CABIN. DECLARED EMERGENCY, SELECTED MANUAL. ANNUCIATOR EXTINGUISHED, COCKPIT COOLED DOWN & SMOKE DISIPATED 15-20 SECS AFTER SELECTING MANUAL. AFTER LANDING, BLACK SMOKE STAINS EVIDENT ABOVE VENTS BETWEEN COCKPIT SEATS & SIDEWALL ON BOTH SIDES. ARFF INFARED HEAT DETECTOR ALSO INDICATED HOT DUCTS IN CABIN ALONG FLOOR ON BOTH SIDES. TROUBLESHOT SYSTEM & REPLACED DUCT TEMP SENSOR WITH AN INSPECTION UNIT. REPLACED COCKPIT SENSOR WITH NEW UNIT. PERFORMED GOOD TEMP CONTROL SYS FUNCTIONAL CHECK REF CMP 210036 & MM 21-60-00. ORIGINAL SQUAWK NOT RESOLVED. R&R PRSOV (RT) WITH REPAIRED UNIT. OPS CHECK GOOD. BUT ORIGINAL SQUAWK NOT RESOLVED. REF CMP 213102. CONTINUED TROUBLESHOOTING. FOUND EMERGENCY AIR VALVE NOT CLOSING COMPLETELY. R&R EMER AIR VALVE WITH AN OVERHAULED UNIT. REMOVED COCKPIT DUCT TEMP SENSOR & INSTALLED INSPECTED SENSOR. REMOVED COCKPIT TEMP SENSOR & INSTALLED NEW TEMP SENSOR. PERFORMED LEAK & OPS CHECK PER MM 21-80-01 AND CMP 216301, 210023, 210036. REPLACED RT PRSOV WITH REPAIRED PRSOV PER MM 21-20-04 AND CMP 213102. REPLACED EMERGENCY AIR VALVE WITH OVERHAULED VALVE . OPS CHECK GOOD. INSTALLED REPAIRED PRSOV VALVE, INSTALLED GASKET. [ORIGINAL SUBMISSION DATE OF SDR: 4/27/2009. ADP]