As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CLIMBING THROUGH 10,000 FT THE AMBER "PITCH FEEL FAIL" CAS MESSAGE CAME ON AND REMAINED ON FRO APPROX 15 MINUTES. PITCH CONTROL FELT NORMAL WHILE HAND FLYING. COMPLIED WITH PITCH FEEL FUNCTIONAL TEST IAW MM 27-30-00 WITH NO DEFECTS OR FAULTS NOTED IN SYSTEM. SYSTEM OPS CHECK GOOD PER MM 27-30-00.