What was found
AFTER TAKEOFF, LT MAIN DID NOT RETRACT. UNLOCK LIGHT ON. R & R LT UPLOCK SWITCH IAW MM 32-60-00, OPS CHECK GOOD. NO DISC NOTED. ALSO FOUND NOSE STRUT NEEDED TO BE SERVICED, SERVICED NOSE STRUT IAW 32-20-00-600 CYCLED LANDING GEAR. OPS CHECK GOOD, NO DISC NOTED.