What was found
RT MLG LIGHT WOULD NOT COME ON. PERFORMED EMERGENCY GEAR EXTENTION PROCEEDURE IAW CHECKLIST & THE LIGHT WOULD NOT COME ON. THE GEAR WARNING HORN SOUNDS WHEN THE BATTERY IS TURNED ON. REMOVED RT MLG ACTUATOR AND INSTALLED UNIT INSPECTED BY MFG IAW MM 32-30-04. LEAK & OPS CHECKED GOOD.