Service difficulty report · Circuit Breaker · Cessna 750

Difficulty date
March 6, 2011
Submitted
March 8, 2011
Operation
Air carrier
Aircraft
N930QS
Make and model
Cessna 750
Aircraft serial
7500130
Aircraft time
9,188 hours, 5,626 cycles
Part
Circuit Breaker
Part number
S2899L75
Condition
Failed
Location
Pitot
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AMBER CAS L STATIC HEAT FAIL. ALSO L PITOT HEAT FAIL. RESET CIRCUIT BREAKER. OPS CHECKED GOOD ON GROUND. REMOVED LT CIRCUIT BREAKER PANEL. OHMED THROUGH PITOT/STATIC CIRCUIT BREAKER AND HAD HIGH RESISTANCE ACROSS TERMINALS. REMOVED CIRCUIT BREAKER AND INSTALLED NEW CIRCUIT BREAKER.- INSTALLED LT CIRCUIT BREAKER PANEL OPS CHECKED GOOD. WORK DONE IAW MM 24-51-00.