What was found
NOSE GEAR DID NOT RETRACT AFTER TAKEOFF. MLG RETRACTED NORMAL & INDICATORS WENT OUT. NLG INDICATOR LIGHT REMAINED ILLUMINATED. HYDRAULIC LIGHT CYCLED NORMAL & WENT OUT AFTER FLAPS & MLG RETRACTED. LANDED NORMAL. POST FLIGHT INSPECTION SHOWED NO ABNORMAL INDICATION OR HYD LEAKS IN OR AROUND NLG. STRUT APPEARED NORMAL. CHECKED NLG UPLOCK SWITCH & WIRING AT CONNECTOR PN022 & NLG DOWNLOCK SWITCH & WIRING AT CONNECTOR PN021 IAW WDM 32-60-01, WIRES & SWITCHES CHECKED GOOD. CYCLED GEAR 15 TIMES WITH NO FAULTS. OPS CHECKED GOOD IAW MM 32-01-00.