What was found
LIGHT SMOKE IN THE ENTIRE CABIN, MORE DENSE IN THE REAR PART WITH WING ANTI-ICE SWITCH TURNED ON. CABIN SIDE WALLS WERE HOT TO TOUCH. SHUTOFF WING ANTI ICE, SMOKE CLEARED AND ODOR DISSIPATED. FOUND INSULATION BAGS RESTING ON WING ANTI-ICE LINES. REPOSITIONED AND TAPED INSULATION BAGS TO PROPER CLEARANCES IAW MM CH 30-10-00. PERFORMED DUCT LEAK CHECK AND WING LEAK EDGE ANTI-ICE TEST. OPS AND LEAK CHECKED GOOD IAW MM 30-10-00.