As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION REMOVED FORM PANEL LAND AT ACCESS HOLE 512 TO MAR DEPTH OF .123 EXCEEDS SPEC. COMPLETED EDDY CURRENT NDI IAW NDT MAIN 20-00-00 NO CRACKS DETECTECED. FLAP OPENED DONE IAW PO 2/21 TREATED AND PRIMED FILLED WITH 9394 SANDED ALODINED AND PRIMED, ACCOMPLISHED REPAIR DEFINITION REPORT S-750-0133/15RD DATED 2-21-12 FAA FORM DATED 2-20-12. OK TO CLOSE ACCESS PANEL 3-12-12