What was found
ON APPROACH FLAPS FAILED AT 5 DEGREES/SLATS EXTENDED. COMPLIED WITH FLAPS FAIL CHECKLIST AND DIVERTED. FLAP FAULT CODE IS 467. UNABLE TO DUPLICATE DISCREPANCY. CONFIRMED BITE 4, 6, 7. CONTACTED TEAM 10. HELD EACH FLAP PANEL UP WHILE EXTENDING FLAPS. NO DEFECT NOTED. CHECKED FLAP CONTROLLER GROUND (PIN 21). GROUND CHECKED GOOD. CHECKED SOFT START MODULE GROUND AT TERMINAL C2. GROUND CHECKS GOOD. CHECKED FLAP RESOLVER VOLTAGES WITH FLAPS IN ALL POSITIONS. VOLTAGE CHECKED GOOD. CLEANED FLAP CONTROL HANDLE IAW MM 27-50-00.