As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PRIMARY STAB FAILED AT 23000 FEET WITH ASSOCIATED CAS MESSAGES. PRIMARY TRIM POWER CIRCUIT BREAKER TRIPPED WITH A FAINT BURNING ODOR. R & R THE PRIMARY STAB TRIM CIRCUIT BREAKER . OPS CHECKED GOOD. WORK DONE IAW MM 24-52-00 & 750 WIRE DIAGRAM MANUAL 27-40-01.