Service difficulty report · Relay · Amd FALCON2000

Difficulty date
May 5, 2016
Submitted
May 9, 2016
Operation
Air carrier
Aircraft
N253QS
Make and model
Amd FALCON2000
Aircraft serial
153
Aircraft time
12,593 hours, 7,750 cycles
Part
Relay
Part number
100CC01AY1
Part serial
8724
Condition
Failed
Location
Window Heat
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WITHIN 5 MINUTES AFTER TAKEOFF AN ELEC BURNING RUBBER SMELL BECAME NOTICEABLE. SOURCE & LOCATION NOT DETECTABLE. ODOR SMELL MOST NOTICEABLE IN COCKPIT & SLIGHTLY NOTICEABLE IN CABIN. OPERATED WINDSHIELD HEAT & NOTICED THE LT WINDSHIELD HEAT WAS NOT WORKING PROPERLY. TROUBLE SHOT LT WINDSHIELD HEAT IAW FIM 30-41-00-810-901 & FOUND HEAT CONTACTOR L512DG TO BE INTERNALLY FAILED POSSIBLY CAUSING SMELL, WE ALSO FOUND WINDSHIELD HEAT RESISTOR BOX L503DG TO HAVE BURN MARKS INSIDE. R & R WINDSHIELD HEAT CONTACTOR, OLD & NEW PN 100CC1AY1, OLD SN 8724, NEW SN 102444. R & R WINDSHIELD HEAT RESISTOR BOX OLD & NEW PN FGFB641830A1, OLD SN 7084, NEW SN 7114. WINDSHIELD HEAT OPERATES NORMAL IAW MM 30-41-00-710-801.