What was found
DAMAGE FOUND IN TAILSTAND AREA WHILE INSTALLING TAIL STAND PRIOR TO MAINTENANCE. NO RECORD OF DAMAGE FOUND. REMOVED TAIL STAND BRACKET, PN 6712405-10 IAW SRM 51-40-03. IAW ENGINEERING REQUEST, RECONTOURED CREASED AREA AND BLENDED SHARP EDGES. STARTED FITTING NEW 6712405-10, BRACKET IAW EEDS DWG 6712405. ACCOMPLISHED ET NDI OF BLENDED AREA IAW NDTM PART 6-20-00-02. NO INDICATIONS FOUND. ACCOMPLISHED UT THICKNESS TESTING IAW NDTM, PART 4-20-10-01. ACCOMPLISHED UT BOND TESTING OF STRINGER IN BLENDED AREA IAW NDTM PART 4-20-00-03. A REPORT HAS BEEN SENT TO ENGINEERING FOR REVIEW. OK TO INSTALL NEW TAIL STAND BRACKET. INSTALLED NEW TAIL STAND BRACKET, PN 6712405-10 IAW EEDS DWG 6712405. FILLET SEALED EDGES OF STRINGER 17. ALL WORK ACCOMPLISHED IAW ENGENEERING REPAIR DEFINITION REPORT S-750-0055/27PRD. ACCOMPLISHED STRUCTURES MODEL NR: 750, REPORT NR: S-750-0055/27RD, REPAIR OF TAILCONE STAND DAMAGE.