As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY EXIT LIGHT ABOVE THE CABIN DOOR REMAINED ON AFTER SHUTDOWN. SIGNOFF. REMOVED CENTER PEDESTAL PANEL 224BR TO GAIN ACCESS TO THE NR 1 EMERGENCV INERTIAL SWITCH. ONCE SWITCH WAS RESET THE CABIN DOOR EMERGENCY EXIT LIGHT TURNED OFF. PERFORMED OP CHECK OF THE EMERGENCV LIGHTING. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED. REINSTALLED PANEL 224BR. ALL WORK DONE, IAW CE680A AMM 33-50-11.