What was found
UNABLE TO EXTINGUISH AMBER CABIN DOOR OPEN CAS MESSAGE. DOOR HANDLE STIFF TO OPERATE AND DOES NOT FEEL FULLY SEATED WHEN CLOSED. THE AUDABLE SOUND OF THE LOCKING PINS LATCHING DOES NOT OCCUR. THE 6 VISUAL INDICATORS SHOW BOLTS IN PLACE. REPLACED CABIN DOOR PCB NZ103 WITH A CUSTOMER SUPPLIED NEW PART I/NW CE-700 AMM 45-00-00 AND WIRING MANUAL 52-00-01. REMOVED AND REPLACED CABIN DOOR THRESHOLD WIRE HARNESS ASSEMBLY WITH A CUSTOMER SUPPLIED NEW PART I/NW CE700 AMM 52-10-00. PERFORMED OPERATIONAL CHECK, IAW CE700 MM 24-60-25-5, OPERATIONAL CHECK SATISFACTORY, NO FAULTS PRESENT.