What was found
FLAP FAIL YELLOW CAS: FCE1 FAIL CAUSING FLAP FAIL INDICATION. SWPS FAULT, SPOILER FAULT AND PTRIM BKP FAIL EICAS. COMPLETED QRH PER AOB 20-05 GUIDANCE. (FCE FAILURES) "CORRECTIVE ACTION" NO FAULTS NOTED ON POWER UP. PERFORMED CMC DOWNLOAD AND SENT TO CONTACT CENTER IAW EMB505AMM 45-45-00. INSPECTED FCE1 CONNECTIONS WITH NO DEFECTS NOTED IAW EMB505 WM 27-03-50-3 PER FIM 27-36-000. PERFORMED THE IASP HEATING SYSTEM TEST IAW EMB 505 AMM 30-30-00 AND PERFORMED THE OPERATIONAL TEST OF THE ADS IAW EMB505 AMM 34-15-00. ALL OPERATIONAL TEST NORMAL. NO DEFECTS NOTED.