Service difficulty report · Battery Pack · Emb EMB505

Difficulty date
June 20, 2021
Submitted
June 23, 2021
Operation
Air carrier
Aircraft
N345QS
Make and model
Emb EMB505
Aircraft serial
50500230
Aircraft time
5,188 hours, 4,031 cycles
Part
Battery Pack
Part number
6450LS00
Part serial
002108
Condition
Faulted
Location
Emergency Lights
Stage of operation
TX
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CABIN EMERG LIGHT: WITH THE EMER LIGHT SWITCH IN THE ARMED POSITION THE CABIN EMERGENCY LIGHTS ILLUMINTED, ALSO WITH THE EMER LIGHT SWITCH IN THE ARMED POSITION THE "EMER LIGHTS NOT ARMED" CAS MESSAGE ILLUMINATED. // SIGN OFF // TROUBLE SHOT TO A FAULTY EMERGENCY BATTERY #2 EVALUATED BATTERIES 1 & 2 WITH BATTERY #1 DISCONNECTED AND #2 CONNECTED EMERGENCY LIGHTING REMAINED REFER TO FIM 33-50-00-810-801-A EMERGENCY BATTERY #2 NEEDS TO BEREPLACE ALSO CHECKED WIRING P2056 FOUND NO ISSUES 28VDC TO CONFIRM COULD NOT DUPLICATE ANYTHING ELSE CONTACTED MCC REPLACE BATTERY #2 PN 6450LS-00 SN 002108 AND RECOMMENDED TO ORDER RELAY AND INERTIA SWITCH AS PRECAUTION CONNECTED NEW BATTERY EMERGENCY 7450LS S/N 005108 APPLIED POWER ON "ON" POSITION ACCORDING TO MANUAL LIGHTS FLASH AFTERWARDS PLACE SWITCH ON ARM POSITIONTO CHARGE FOR 90 MINUTES DUE TO NEW BATTERY WITH BATTERY NO RESIDUAL CHARGE. BATTERY REQUIRED CHARGE NEW BATTERY NOT FULLY INSTALLED ON MOUNTS ONLY CONNECTED OLD BATTERY NEEDS TO BE REMOVED REFER EMB505S AMM 33-50-00 NEW BATTERY PLACED ON ARM CHARGE SINCE 0400 HOURS 06-21-2021 IF LIGHTS-KEEP FLASHING POSSIBLY BATTERY BAD FROM STOCK OR MORE TROUBLESHOOTING REQUIRED FIM 33-50-00-810-8 PERFORMED EMERQENC LIAHTS OPERATIONAL CHECK AAAIN TO ISOLATE CAUSE OF . FLASHING LIGHTS. AS PER AMM INSTRUCTIONS, SELECTED EMER. LIGHTS SWITCH TO ON AND ALLOWED THE BATTERY TO DISCHARGE UNTIL THE FLIGHTS FLASH (ROUGHLY 25 MINS). NEXT,1 SET SWITCH TO ARM FOR 90 MINS TO CHARGE. LIGHTS STILL FLASHED, BUT AFTER CYCLING POWER, FLASHING GOES AWAY. HOWEVER, WHEN SETTING SWITCH TO ARM, N LIGHTS COME ON, THEY ARE SUPPOSED TO STAY OFF AND STAY IN STANDBY CHARGING. REPEATED FIM PROCEDURE AGAIN. DISCONNECTED #2 BATTERY AND SET SWITCH ON ARM, THIS TIME THE LIGHTS STAY OFF IN STANDBY AS THEY SHOULD BE. RE-CONNECTED BATTERY AND CONFIRMED LIGHTS COME BACK ON IN ARM POSITION. BATTERY IS BAD FROM STOCK. INFORMED MCC AND ORDERED ANOTHER.REF AMM 33-52-01 REMOVED AND REPLACED EMEGENCY BATTERY #2 AS REQUIRED N

More about the Emb EMB-505