What was found
MAIN DOOR HANDLE: WHILE CLOSING MAIN DOOR FROM INSIDE, DOOR HANDLE JAMS ABOUT HALFWAY DOWN. NEEDS EXTRA PRESSURE TO CLOSE. // SIGNOFF// INSPECTION VERIFIED DISCREPANCY. GAINED ACCESS TO DOOR LINKAGE AND LUBED AS REQUIRED. LUBED DOOR LATCHES AND STRIKERS PERFORMED DOOR RIGGING AND T/S REMOVED PCB NIC105 AND INSTALLED A NEW PCB. PERFORMED MULTIPLE SATISFACTORY OPS CHECKS WITH NO DISCREPANCYS NOTED WORK PERFORMED IAW CE-680A AMM 52-70-00 AND 24-60-40