What was found
ANTISKID FAIL AMBER CAS: ON CLIMB OUT WE HAD A FLICKERING AMBER ANTISKID FAIL CAS MESSAGE. THE CHECKLIST HAD US TURN IT OFF SINCE THE MESSAGE WOULD NOT CLEAR. WE LANDED IN THE OFF POSITION. // SIGNOFF // REMOVED THE ANTI-SKID CONTROLLER AND INSTALLED SERVICEABLE CONTROLLER FROM N324QS, PERFORMED ANTI-SKID CONTROLLER OPERATONAL CHECK JAW CE680 MM 32·42·00. OPS CHECK GOOD. NO FAILS NOTED. PERFORMED FUNCTIONAL CHECK OF THE ANTI"SPIN SYSTEM IAW CE680,MM 32·42·00. FUNCTIONAL CHECK GOOD. NO FAILS OR FAULTS NOTED.