What was found
EMERGENCY LIGHTING: INTERIOR EXIT SIGN TO THE LEFT OF MAIN ENTRY DOOR IS INOP. // SIGNOFF// GAINED ACCESS TO INTERIOR EXIT SIGN BY REMOVED MED SIDE TRIM PANELS. FOUND CONNECTOR NOT SEATED SLL THE WAY. SECURED CONNECTOR AND PERFORMED OPS CHECKS WITH NO DEFECTS NOTED. CLOSED OUT ALL ACESS GAINED. !AW EMB-505 AMM 33-52-13.