What was found
CABIN DOOR OPEN AMBER CAS: CABIN DOOR OPEN CAS MESSAGE WILL NOT EXTINGUISH WHEN CLOSING MED., DOOR OPEN LIGHT IN DOOR STAYS ILLUMINATED. TRIED RESET PROCEDURE AND POWERED DOWN A/C, BOTH UNSUCCESSFUL. //SIGNOFF// PERFORMED DOOR RESET, RESET FAILED INTERREGATED CMC AND FOUND SECURRING PAWL DOOR SWITCH READING HANDLE SECURED WHEN HANDLE WAS OPEN. GAINED ACCESS TO THE S6 SENSOR BY REMOVING THE MED DOOR STEPS AND FOUND CONNECTOR PC058 LOOSE RESECURED CONNECTOR AND PERFORMED RESET OPERATIONAL CHECKS GOOD RESECURED ACCESS GAINED NO DEFECTS NOTED REF CE-680A AMM 52-10-50 AND CE-680A AMM 45-40-00.