What was found
GEAR DISAGREE L AMBER CAS: LEFT, RIGHT, AND NOSE DISAGREE MESSAGE CAME ON AFTER TAKEOFF DURING GEAR RETRACTION. LANDING GEAR INDICATIONS ON EICAS WERE ALL AMBER AND BOXED. QRH PROCEDURES WERE ACCOMPLISHED. LANDING GEAR EXTENDED NORMALLY AND AN UNEVENTFUL LANDING WAS ACCOMPLISHED.//CORRECTIVE ACTION// T/S SYSTEM TO FAULTY LANDING GEAR HANDLE. R/R GEAR HANDLE AND PERFORMED GEAR SWINGS. NO DEFECTS NOTED.
PN OFF 9912750-2 SN OFF 661 PN ON 9912750-2 SN ON 291