What was found
MAINTENANCE REPORTS THAT THE MAIN CABIN DOOR HANDLE IS STUCK IN THE OPEN POSITION. // SIGNOFF// ATTEMTED TO CLOSE MED DOOR DUPLICATED FAULT FOUND THAT THE MIDDLE AFT LOCK PIN WAS PUSHED IN. GAINED ACCESS BY REMOVING MED STEP AND INSPECTED LOCK PIN ASSEMBELY AND LINKCAGES WITH NO DEFECTS NOTED RE ADJUSTED LOCK PIN AND RESECCURED ACCESS GAINED PERFORMED MULTIPLE OPS CHECKS WITH NO FAULTS. OPERATIONAL CHECKS GOOD REF CE-680A AMM 52-10-07 AND CE-680A AMM 52-10-00.